A motion sensor-controlled switch permitted under subsection 27.5 of this by- law shall:

  • be designed for fail-safe operation so that if the motion sensor-controlled switch fails, the electrical fixture that it controls activates;
  • (b) be of a type, the operation of which is not impaired by the presence of smoke;
  • (c) control an area that is not more than 240 square metres;
  • (d) if the illumination is for an access to exit:
  • (i) maintain an average level of illumination of 10 lux at all times, and
  • (ii) in addition to subparagraph
  • (i) above, maintain the illumination within its area of control active for not less than 15 minutes after the activity that caused the lighting to activate has stopped or left its area of control;
  • (e) if the illumination is for a space that is an access to exit from a residential area:
  • (i) activate all lighting between vertical partitions in the space,
  • (ii) activate all lighting within the space within two seconds of any movement either in or directly related to the area controlled by the motion sensor control switch; By-law Number 6543-23
  • (f) provide coverage to all of the space so that there are no null zones.

Extrait court. Le reste du texte est sur la source officielle.

Source officielle · Table des matières

Pour signaler une correction : info@bylawinsider.com. Ce lien ouvre votre programme de courriel.

Copie non officielle, pour faciliter la lecture. La version officielle prévaut. Source officielle

Short excerpts of a public bylaw PDF. The official PDF governs.