Documentation The following represents the minimum information which shall be contained in a report of an investigation where the above procedure was used.
- (a) Description of Area
- (i) Location and description of the blasting operation.
- (ii) Dimensioned sketch including photographs, if possible, of the location of the blasting operation, the nearest premises and the measurement location.
- (iii) Description of the measurement location.
- (iv) Physical and topographical description of the ground surface.
- (v) Meteorological conditions at the time of the investigation, including approximate wind speed in km/h, wind direction, air temperature in degrees Celsius, approximate relative humidity, degree of cloud cover and whether or not a condition of thermal inversion prevailed.
- (b) Instrumentation All the equipment used for making sound and vibration measurements shall be listed, including:
- (i) type, model and serial number of Peak Pressure Level Detector;
- (ii) type, model and serial number of microphone;
- (iii) type. model and serial number of Acoustic Calibrator;
- (iv) windscreen;
- (v) extension cables and additional amplifiers, if used;
- (vi) type, model and serial number of Vibration Velocity Detector;
- (vii) type, model and serial number of transducers.
- (viii) type, model and serial number of vibration calibrator. By-law 2006-140 36 Office Consolidation The Corporation of the City of Barrie Noise By-law
- (c) Sound and Vibration Data The measurement details shall be described, including:
- (i) the location where measurements were taken, the time period involved and the orientation of instrumentation using a sketch, if necessary;
- (ii) details of all calculations;
- (iii) the peak pressure level in dB and/or peak particle velocity in cm/s;
- (iv) comparison with applicable peak pressure limits and/or peak particle velocity limits.
Extrait court. Le reste du texte est sur la source officielle.
Source officielle · Table des matières
Sujets
Articles voisins
- 5(2)
- 5(3)
- 6 Exterior Sound Level Measurement Procedure For Powered Mobile Construction Equipment - SAE J88a SAE J88a Recommended Practice is adopted by the Ministry with the following change
- 7 MEMAC Test Code For the Measurement of Sound From Pneumatic Equipment The MEMAC Test Code For The Measurement Of Sound From Pneumatic Equipment is adopted by the Ministry with the following additional requirement