For guards within dwelling units and for exterior guards serving not more than two dwelling units, Table § 629-19C(7) need not apply where the guard construction has been demonstrated to provide effective performance. Table § 629-19C(7) Specified Loads for Guards Forming part of Subsection C(7)(a) Minimum Design Loads Horizontal Load Applied Horizontal Load Inward or Applied Inward or Outward at Outward on Elements Evenly Distributed any Point at Within the Guard, Vertical Load Location of the Top of the Including Solid Panels Applied at the Top Guard Guard and Pickets of the Guard Guards within 0.5 kN/m or 0.5 kN applied over a 1.5 kN/m dwelling units concentrated maximum width of and exterior load of 1.0 kN 300 mm and a height of