34
Where the fire route is not used as part of a service road, it shall be constructed as follows:
- not less than 9.0 cm. of hot mixed asphalt on not less than 30.0 cm. crushed stone or gravel on a compacted base; or
- (b) not less than 15.24 cm. concrete slab minimum compressive strength 30000 K.Pascals on not less than 15.24 cm. crushed stone on a compacted base.