Règlements municipaux du Canada

www.bylawinsider.com

Bylaw Insider

Répertoire des entreprises et nouvelles sur les règlements municipaux, le stationnement, la sécurité privée et le remorquage.

Navigation principale

Barrie : Règlement no 2006-140, art. 5(4) — Noise By-law

Noise By-law

Vérifié le

Texte indexé

Documentation The following represents the minimum information which shall be contained in a report of an investigation where the above procedure was used.

  • (a) Description of Area
  • (i) Location and description of the blasting operation.
  • (ii) Dimensioned sketch including photographs, if possible, of the location of the blasting operation, the nearest premises and the measurement location.
  • (iii) Description of the measurement location.
  • (iv) Physical and topographical description of the ground surface.
  • (v) Meteorological conditions at the time of the investigation, including approximate wind speed in km/h, wind direction, air temperature in degrees Celsius, approximate relative humidity, degree of cloud cover and whether or not a condition of thermal inversion prevailed.
  • (b) Instrumentation All the equipment used for making sound and vibration measurements shall be listed, including:
  • (i) type, model and serial number of Peak Pressure Level Detector;
  • (ii) type, model and serial number of microphone;
  • (iii) type. model and serial number of Acoustic Calibrator;
  • (iv) windscreen;
  • (v) extension cables and additional amplifiers, if used;
  • (vi) type, model and serial number of Vibration Velocity Detector;
  • (vii) type, model and serial number of transducers.
  • (viii) type, model and serial number of vibration calibrator. By-law 2006-140 36 Office Consolidation The Corporation of the City of Barrie Noise By-law
  • (c) Sound and Vibration Data The measurement details shall be described, including:
  • (i) the location where measurements were taken, the time period involved and the orientation of instrumentation using a sketch, if necessary;
  • (ii) details of all calculations;
  • (iii) the peak pressure level in dB and/or peak particle velocity in cm/s;
  • (iv) comparison with applicable peak pressure limits and/or peak particle velocity limits.

Extrait court. Le reste du texte est sur la source officielle.

Source officielle · Table des matières

Pour signaler une correction : info@bylawinsider.com. Ce lien ouvre votre programme de courriel.

Copie non officielle, pour faciliter la lecture. La version officielle prévaut. Source officielle

Short excerpts of a public bylaw PDF. The official PDF governs.