If an enclosure is of chain link construction the enclosure shall:

  • be constructed of not greater than 38 mm (1.5 inch) diamond mesh; and
  • (b) be constructed of not less than No. 12 gauge galvanized steel wire or of minimum No. 14 gauge steel wire covered with vinyl or alternate approved coating forming a total thickness equivalent to

No. 12 gauge galvanized wire; and

  • (c) be supported by at least 3.8 centimetres (1 ½ inch) diameter galvanized steel posts each embedded in concrete to a minimum depth of 1.2 metres (4 feet) below grade, such posts to be spaced

no more than three (3) metres (10 feet) apart. Top and bottom horizontal rails shall be provided of 3.8 centimetres (1 ½ inch) minimum diameter galvanized steel, except that a minimum No. 9 gauge galvanized steel wire may be substituted for the bottom horizontal steel rail. A vinyl or other approved coating may be substituted for the galvanized coating.