Read a first, second, and third time and passed on June 15 and 16, 2015. "Martha Pettit" "Frank Scarpitti" ____________________________ __________________________ Martha Pettit Frank Scarpitti Deputy Clerk Mayor By-law 2015-96 Schedule “A” to By-law 2015-96 General Provisions for Pool Enclosures Provisions All Properties
- i. Minimum Height of Fences And Gates 1.2 m (4
- ft)
- ii. Maximum Height of Fences And Gates 1.8 m (6 ft.)
- iii. Minimum Distance of Enclosure From 1.2 m (4 ft.) The Edge of The Water Contained In The Pool.
- iv. Maximum Clearance Between Bottom of 100 mm (4 in.) Fence, Gate And Grade By-law 2015-96 Schedule “B” to By-law 2015-96 Wood Fence Construction for Pool Enclosures Provisions All Properties
- i. Horizontal Rail Minimum Size 38 mm (1-1/2 in.) x 89 mm (3-1/2 in.)
- ii. If Minimum Vertical Spacing between 0.9 m (35.4 in.) Horizontal Railings
- iii. Then Maximum Spacing between Vertical 100 mm (4 in.) Boards
- iv. If Minimum Vertical Spacing between Less than 0.9 m (35.4 Horizontal Railings in.)
- v. Then Maximum Spacing between Vertical 38 mm (1-1/2 in.) Boards
- vi. Vertical Board Minimum Size 19 mm (3/4 in.) x 89 mm (3-1/2 in.)
- vii. Fence Post Maximum Spacing 2.4 m (8 ft.)
- viii. Minimum Size of Fence Posts 89 mm (3-1/2 in.) x 89 mm (3-1/2 in.)
- ix. Minimum Depth Below Grade of Imbedded 1.2 m (4 ft.) Fence Posts By-law 2015-96 Schedule “C” to By-law 2015-96 Metal and Wrought Iron Fence Construction for Pool Enclosures Provisions All Properties
- i. Minimum Vertical Spacing between 0.9 m (35.4 in.) Horizontal Railing
- ii. Vertical Railing Maximum Spacing 100 mm (4 in.)
- iii. Minimum Depth Below Grade of 1.2 m (4 ft.) Imbedded Fence Posts By-law 2015-96 Schedule “D” to By-law 2015-96 Chain Link Fence Construction for Pool Enclosures All Properties for All Properties for Posts Provisions Posts Spaced Spaced Maximum 3 m Maximum 2.4 m (8 ft.) (10 ft.)
- i. Minimum 0.9 m (35.4 in.) 0.9 m (35.4 in.) Vertical Spacing between Horizontal Railings
- ii. Maximum Chain 38 mm (1-1/2 in.) 38 mm (1-1/2 in.) Link Mesh Size for 1.2 m (4 ft.) Fencing
- iii. Maximum Chain 38 mm (1-1/2 in.) 38 mm (1-1/2 in.) Link Mesh Size for 1.8 m (6 ft.) Fencing
- iv. Minimum 2.6 mm diameter (no. 2.6 mm diameter (no. Diameter/Gauge 11 gauge) or 2 mm 11 gauge) or 2 mm of Mesh diameter (no. 14 diameter (no. 14 gauge) including Vinyl gauge) with vinyl with vinyl covering Covering covering forming a forming a total total combined combined thickness of thickness of 2.6 mm 2.6 mm (no. 11 gauge) (no. 11 gauge)
- v. Minimum 47.5 mm (1-7/8 in.) 47.5 mm (1-7/8 in.) Diameter Gate and Terminal Posts
- vi. Minimum Depth The steel fence post The steel fence post will Below Grade of will be a minimum of be a minimum of 0.76 m Imbedded Fence 0.76 m (2 ft. 6 in.) imbedded in Posts (2 ft. 6 in.) imbedded a concrete footing in a concrete footing which has a diameter of which has a diameter 20.32 cm (8 in.) and a of 20.32 cm (8 in.) depth of 1.2 m (4 ft.). and a depth of 1.2 m Note: The top of (4 ft.). Note: The top concrete footing may be of concrete footing below grade level may be below grade 10.175 cm to 20.35 cm level 10.175 cm to (4 in. to 8 in.)
Extrait court. Le reste du texte est sur la source officielle.
Source officielle · Table des matières
Articles voisins
- 21.1 The provisions of the Legislation Act, 2006, shall apply to this By- law
- 22.0 Force and Effect
- 20.35 cm (4 in. to 8 in.) vii. Minimum 38 mm (1-1/2 in.) 47.5 mm (1-7/8 in.) Diameter for Intermediate Posts viii. Minimum 32 mm (1-1/4 in.) 41.275 mm (1-5/8 in.) Diameter Top Rail By-law 2015-96 All Properties for All Properties for Posts Provisions Posts Spaced Spaced Maximum 3 m Maximum 2.4 m (8 ft.) (10 ft.) ix. Minimum 3.7 mm (No. 9 gauge) 3.7 mm (No. 9 gauge) Diameter Bottom Wire x. Minimum 32 mm (1-1/4 in.) 32 mm (1-1/4 in.) Diameter Gate Frame - Pipe