Winnipeg : Règlement no 1/2008, art. 77(a) — Neighbourhood Liveability By-law
Vérifié le
Texte indexé
be constructed of masonry, concrete, heavy gauge metal or mesh or other non-combustible materials acceptable to the Chief;
- (b) have a chimney designed and constructed as a proportional and integral part of the fireplace to ensure that an adequate draft is created;
- (c) have its chimney opening entirely covered by a non-combustible spark arrestor, grille or mesh with openings no larger than 12 mm (1/2 in);
- (d) have a side opening to the fire chamber which does not exceed 0.56 2 2 m (6ft ) in area, and in which neither the width nor length is greater than 75 cm (2.5 ft);
- (e) has its side opening entirely covered by a non-combustible spark arrestor, grille or mesh with openings no larger than 12mm (1/2 in); and
- (f) not be used for commercial or industrial applications. By-law No. 1/2008 51 Requirements for outdoor warming fire receptacles
Extrait court. Le reste du texte est sur la source officielle.
Source officielle · Table des matières
Articles voisins
- 76(a)
- 77 Requirements for outdoor fireplaces An approved outdoor fireplace must
- 78 An approved outdoor warming fire receptacle must be a metal receptacle in good repair that has a maximum capacity of 225 litres (50 gallons) with all openings entirely covered by removable, non-combustible spark arrestors, grilles or mesh with openings no larger than 12 mm (1/2 inch)
- 79 Rules regarding all open air fires A person in charge of an open-air fire must ensure that
Pour signaler une correction : info@bylawinsider.com. Ce lien ouvre votre programme de courriel.
Copie non officielle, pour faciliter la lecture. La version officielle prévaut. Source officielle
Short excerpts of a public bylaw PDF. The official PDF governs.