Toronto : Règlement no 629, art. (a) — Chapter 629 Property Standards
Vérifié le
Texte indexé
Except as otherwise provided in this section, a guard not less than 1,070 millimetres high shall be provided:
- [1] Around each roof to which access is provided for other than maintenance;
- [2] At openings into smoke shafts that are less than 1,070 millimetres above the floor;
- and [3] At each raised floor, mezzanine, balcony, gallery, interior or exterior vehicular ramp, and at other locations where the difference in level is more than 600 millimetres.
Extrait court. Le reste du texte est sur la source officielle.