The minimum specified horizontal load applied inward or outward at the top of

every required guard shall be:

  • [1] 3.0 kilonewtons per metre for means of egress in grandstands, stadia, bleachers and arenas;
  • [2] A concentrated load of 1.0 kilonewtons applied at any point for accessways to equipment platforms, contiguous stairs and similar areas where the gathering of many people is improbable;
  • and [3] 0.75 kilonewtons per metre or a concentrated load of 1.0 kilonewtons applied at any point, whichever governs for locations other than those described in Subsection D(5)(a)[1] and [2]. 629-22 April 30, 2025