Windsor : Règlement no 148-2025, art. 5.2.10 — Required Handrails or Guards at Stairs A handrail or guard shall be provided and maintained in good repair as follows
Vérifié le
Texte indexé
Required Handrails or Guards at Stairs A handrail or guard shall be provided and maintained in good repair as follows:
- i. at least one side of stairs less than 1 100 mm in width; ii. two sides of stairs 1 100 mm in width or greater; iii. two sides of a curved stair used as an exit; iv. handrails are not required for stairs
- (i) within dwelling units having not more than 2 risers; or
- (ii) for exterior stairs having not more than 3 risers and serving not more than one dwelling unit. v. only one handrail is required on exterior stairs having more than 3 risers provided such stairs serve not more than one dwelling unit; vi. except as required in
- (b) & (c), one handrail may be provided centrally for stairs up to 2.4 m wide; and vii. handrails shall have a maximum uniform height of 920 mm when measured vertically from a line drawn through the outside of the stair nosing and minimum uniform height of 800 mm.
Extrait court. Le reste du texte est sur la source officielle.
Source officielle · Table des matières
Sujets
Articles voisins
- 5.2.8 Exterior Doors & Windows Exterior doors, windows and skylights shall be maintained in good repair and weather tight. Rotted and defective doors, door frames, window frames, sashes and casings shall be renewed and defective door and window hardware, weather stripping, caulking and broken glass shall be replaced. Repairs to windows shall be
- 5.2.9 Stairs, Porches, Landings, Loading docks, Balconies, Canopies, Awnings, Fire Escapes All stairs, porches, landings, loading docks, balconies, canopies, awnings, fire escapes together with any guard, balustrade, railing, screen or other appurtenance attached thereto shall be maintained in good repair and in a safe and structurally sound condition
- 5.2.10(i) Required Handrails or Guards at Stairs A handrail or guard shall be provided and maintained in good repair as follows
- 5.2.11 Height of Guards A guard shall be installed and maintained in good repair as follows