Installed in conformance with Sentence

  • (c) where a solid fuel-fired combustion appliance exists;
  • (b) Installed on or near the ceiling in each room in which there is installed a solid fuel-burning appliance;
  • (c) Permanently connected to an electrical circuit, and
  • i) shall have no disconnect switch between the over-current device and the carbon monoxide detector where practical;
  • ii) be wired so that its activation will activate all carbon monoxide detectors within the suite, where located within a suite of residential occupancy; and
  • iii) be equipped with an alarm that is audible within bedrooms when the intervening doors are closed, where located adjacent to a sleeping area.
  • (d) Plug-in types of detectors plugged into a duplex receptacle near the floor level are acceptable in locations where there may be a hardship complying with (a),
  • (b) and
  • (c) outlined above.