Guard – Provided
A guard with a minimum height of 900 mm (35 inches) shall be provided and maintained along the open sides of balconies, mezzanines, landings, or other areas where the vertical drop exceeds 600 mm (24 inches), except that a guard of 710 mm (28 inches) minimum height is acceptable for exterior porches, decks and balconies where the vertical drop from the open side exceeds 600 mm (24 inches) but does not exceed 1 800 mm (71 inches).