Barrie By-law 2006-140, s. 3(2) — Noise By-law
Noise By-law
Last checked
Indexed text
Specifications
A sound level meter which meets the following specifications is a General Purpose Sound Level Meter:
- (a) the sound level meter, including a microphone equipped with a windscreen shall meet the specifications of IEC 123, except that, in addition to meeting the specifications of subclause 5.2 thereof, the micro- phone of the sound level meter shall also meet the specifications of subclause 5.2 amended by the substitution therein of an angle of 0 0 incidence of ±3O instead of ±90, as it therein appears, and by the substitution of Table 102-2 hereof instead of Table 1, as it therein appears;
- (b) the sound level meter shall incorporate A-weighting, which is specified in 123 as optional;
- (c) the sound level meter shall have a minimum usable range of sensitivity of from 40 dBA to 100 dBA and it shall read to an accuracy of ±1.0 dB over that range;
- (d) a windscreen shall be installed on the microphone and shall not affect by more than 1 dB the tolerance prescribed in clauses
- (a) and (c); By-law 2006-140 19 Office Consolidation The Corporation of the City of Barrie Noise By-law
- (e) the sound level meter, including a microphone equipped with a windscreen, shall, when operated in the presence of wind, indicate a wind-induced sound level not in excess of the relevant value listed in Table 102-3.
Short excerpt. The rest of the text is on the official source.
Official source · Table of contents
Topics
Related sections
Other cities
To report a correction: info@bylawinsider.com. This link opens your mail program.
Unofficial copy for convenience; the official version governs. Official source
Short excerpts of a public bylaw PDF. The official PDF governs.