Barrie By-law 2006-140, s. 5(2) — Noise By-law
Noise By-law
Last checked
Indexed text
Specifications
A sound level meter which meets the following specifications is a Peak Pressure Level Detector (the features of this device are incorporated in an Impulse Sound Level Meter as specified in section 4 above):
- (a) the microphone of the sound level meter, when equipped with a windscreen, shall perform within a tolerance of ±1 dB throughout the frequency range of from 5 Hz to 31.5 Hz in the circumstances and conditions for use set out in Table 1 of IEC 179;
- (b) the sound level meter without the microphone shall be capable of providing linear response as specified in subclause 4.5 of IEC 179, within
a tolerance of ±1 dB throughout the frequency range of from 5 Hz to 15 kHz;
- (c) the sound level meter shall incorporate the optional characteristics specified in subclause 4.5 of IEC 179A;
- (d) the sound level meter shall meet the specifications set out in IEC 179 clause 3, subclauses 4.1, 4.2, 4.4, 4.5, 4.7, 4.8, clause 5, subclauses 6.2, 6.3, 6.4, 6.5, 6.8, 6.9, 7.1 through 7.9, 7.11, 8.1, 8.2, 8.3, 8.6 through 8.9 and the appropriate specifications of clause 10. By-law 2006-140 20 Office Consolidation The Corporation of the City of Barrie Noise By-law
Short excerpt. The rest of the text is on the official source.
Official source · Table of contents
Topics
Related sections
Other cities
To report a correction: info@bylawinsider.com. This link opens your mail program.
Unofficial copy for convenience; the official version governs. Official source
Short excerpts of a public bylaw PDF. The official PDF governs.